Search :  
 
You now position----Porduct----Can Making----3-piece Can Testing
Porduct name :  DER-3 Digital Enamel Rater



Detailed information Browsing more

DER-3 Digital Enamel Rater  is the industry standard.   
The new CANNEED Enamel Rater DER-3 instrument test the coverage of the enamel coating 
inside food and beverage cans. Also aerosol-cans may be tested with DER-3 Digital Enamel Rater.   
It displays an index of the amount of metal exposed by incomplete enamel coverage on a clear, 
easily read digital LED.  The instrument applies a constant voltage across the can body  
and an electrode immersed in an electrolyte-filled can,  and measures the resulting current.   
Test voltage is set at 6.3 VDC.  Operating range is 0 to 300 milliamperes   
with accurate resolution within 0.1ma.    

The instrument operates in industry standard 4 second mode, continuously, or can be programmed 
to measure any desired time. In 4-second mode, the display shows the reading only at 4 seconds.   
In continuous mode the reading is displayed beside elapsed time with the 4-second reading 
automatically stored in memory for recall. A simple and foolproof calibration self-test verifies  
correct, accurate operation.   

Location of exposed metal can be determined by reversing voltage  which causes bubbles 
of gas to form on exposed metal for easy visual identification.  Electrolyte level and can 
contact sensors ensure that testing begins only when can is properly filled with electrolyte 
solution and good electrical contact with the can has been established.   

The sturdy enclosure includes a sealed-membrane keypad for protection against moisture 
and corrosion in the factory environment.  An RS232 serial interface permits use with 
remote computers,  printers or data collectors.   

The CANNEED End Panel Holder can be used with any CANNEED Enamel Rater to test 
for metal exposure on can ends.  The test is performed in the same manner as on a can.   
Electrolyte is added to the plastic cup, the can end is fitted onto the beveled end of the cup,   
and a vacuum is applied to hold the end securely on the cup.  

When the cup is inverted, the elctrode and can end become immersed in the electrolyte 
and the reading is displayed on the Enamel Rater.   
   
The CANNEED End Panel Holder consists of a lucite cup mounted to rotate on its horizontal axis.   
The cup is beveled to make a tight seal on the can end. An electrode and vacuum connection 
are mounted within the cup.  On the bakelite base a vacuum stopcock and a moveable contact arm,   
which completes the electrical circuit when the assembly is inverted.  A cable adaptor footswitch 
 is required to connect a CANNEED End Panel Holder to the CANNEED Digital Enamel Rater.  

Technical Specifications (changes reserved):  
Sample type    : 2- and 3-piece cans. Also aerosol-cans  
Range: 0 to 300 ma  
Resolution: 0.1mA  
Accuracy: +/- 5%  
Rear Panel: RS232 serial output
 




Home |  Porduct |  Technical data |  Consultation |   Canneed company |  Contacts |  .